Configuring the Site
WinLink User and Installation Guide
Version 1.750
5-91
Note:
Any change to these parameters is effective immediately.
Each side of the link can be configured separately.
•
The following list details common configurations; both sides
are must be configured with the same parameter.
•
Standard (Default) Configuration for Ethernet Applications
•
Set IDU aging to 300 seconds, ODU set to Bridge mode
•
Fast aging mode – for rapid network topology changes
•
Set IDU aging to one second, ODU set to Hub mode.
•
Hub Mode
•
The ODU is set to HUB mode. IDU aging is not applicable.
•
Ethernet Bridge
The ODU is set to Bridge mode. The IDU aging is not applicable.
Configuring Ethernet Mode
The Ethernet mode is configurable for line speed (10/100BaseT) and
duplex mode (half or full duplex). This mode provides an Auto detect
feature where the line speed and duplex mode are detected
automatically using auto negotiation. Use the manual configuration
when external equipment does not support auto negotiation. The
default setting is Auto Detect.
The maximum Ethernet Information Rate can be limited via the pull
down menu. The default setting is Best Effort.
Note:
It is not recommended to configure the port that is used for the
management connection, since a wrong configuration can cause
management disconnection or Ethernet services interruption.
Æ
To configure the Ethernet Mode:
1.
From the
Configuration
menu, select the site to reconfigure.
The Site Configuration dialog box opens.
2.
Click
Advanced > Ethernet
.
3.
In the Ethernet Ports Configuration pane, use the drop-down menu
to select the LAN configuration.