Performance Monitoring
WinLink User and Installation Guide
Version 1.750
6-117
Table
6-5: Alarms and Information Messages
Message Description
Radio Link – Sync
Radio link is synchronized
Radio Link – Out Of Sync
Radio link lost synchronization
Link Has Been Reset
ODU was reset due to internal problem
TDM Interface – Normal
TDM interface is operating properly
TDM Interface – LOS
Loss of Signal is reported by TDM interface
TDM Interface – AIS
Alarm Indication Signal is reported by TDM interface
TDM Interface – Loopback
A loopback is active on TDM interface
Link Resetting
Wireless link reset from the management station. This
alarm is caused by automatic reset after link configuration.
Local ODU Resetting
The local ODU reset from the management station.
Monitor was stopped since no
connection to the link
No ODU-to-IDU traffic was detected during the last 20
minutes.
TDM Service – Normal
TDM service is operating properly
TDM Service – Alarm
Error has been detected on a TDM line
Configuration problem detected
The link needs to be reinstalled
Channel Scanning in progress
The ODU is scanning the channels for the remote ODU
Transmitting on <frequency> GHz
The ODU is transmitting on the frequency channel listed
Radar activity was detected in
<site>, on channel <frequency>
GHz
For DFS versions only. Radar is detected; the channel is
prohibited for 30 minutes.
Monitoring fo Radar activity on
channel <frequency> GHz
For DFS versions only. ODU is looking for Radar activity.
Bit Failed indication
Indicates ODU hardware problem. Send error code to
Technical Support.
Link Status
Indicates incorrect connection or incompatibility between
versions. Available in 1.620 versions and above.
Site Status
Indicates incorrect connection or operation at the site.
Available in 1.620 versions and above.
The events are displayed in the Events log in the lower part of the
WinLink™ 1000 Manager Main menu: