Connecting Power to an O-PoE
WinLink User and Installation Guide
Version 1.750
3-40
•
Connect the power cable plug to the mains outlet.
The unit turns on automatically upon connection to the mains.
To connect DC power to an IDU
A special 3-prong socket for DC power connection is supplied with the
unit.
Connecting Power to an O-PoE
AC power is supplied to the O-PoE via a 3m (10 ft) 3 wire AC cable
attached to the unit (pigtail). The AC cable is provided with no
termination.
To connect AC power to an O-PoE:
Connect the power cable to a protected/shielded AC mains outlet.
The AC mains outlet should be provided with circuit breaker rated 5A
according to the local national electrical code.
The unit will be turned on automatically upon connection to the mains.
To maintain Overvoltage (Installation) Category II, install a suitable
surge suppressor device in the branch circuit to limit expected
transients to Overvoltage Category II values.
The limits are based on IEC60664 and are also located in Table 2H of
UL60950 (for mains
≤
150V, the transient rating is 1500V;
for 150V < mains
≤
300V, the transient rating is 2500V;
for 300V < mains
≤
600V, the transient rating is 4000V).
Aligning Antennas with the Beeper
Perform the antenna alignment using the ODU’s audible tone. The tone
is not suitable for aligning the All Indoor Units (AIND). To align an
AIND system, see Appendix C: AIND Alignment.
To speed up the installation time, alignment of a Winlink™ 1000
system should be performed by two teams simultaneously, at site
A and at site B.
Æ
To align the ODUs using the alignment tone:
1.
Verify that power is connected to the IDUs at both sites.
Do not stand in front of a live ODU.
Warning
Warning