Radiolink Electronic Ltd
77
ADJUSTABILITY:
• On/off may be separate from speed switching by plugging governor on/off into CH8 and changing
CUT-CH setting.
• If using separate on/off, switch assignment is totally adjustable. Be careful not assign governor off
to a condition switch if you want the governor to function in that condition.
• Speed switching and governor ON/OFF may be together using one switch or ON/OFF switching
may be performed using an independent switch/channel.
• When speed setting control uses CH7 and separate ON/OFF switch is not used, CH8 can be used
for other functions.
• In-flight adjustment of the head speed (for easy adjustment during turning) may be created using
an additional channel and a programmable mix.
The GV-1 controls throttle when it is active, so the throttle will not obey any Failsafe settings preset
for throttle in the transmitter. Always set the Failsafe setting for the GV-1's on/off channel to OFF.
This way the governor is shut off and the throttle obeys the Failsafe throttle commands.
Goals
Steps
Inputs
Set up a governor to use
both channels into the receiver
and switch between the
Open and activate the
GOVERNOR
Function.
to BASIC menu,
again to
ADVANCE
to GOVERNOR