SV-360HD 3D Camera System
33
SV-360HD 3D Camera Installation/Configuration Guide
Radio Engineering Industries, Inc. | 6534 L Street | Omaha, NE 68117
© 2018 Radio Engineering Industries, Inc.
800.228.9275 | p: 402.339.2200 | f: 402.339.1704 | radioeng.com
3.9
Other Settings
Other Settings Window
Menu Item
List Options
Description
Hazard Blinker Trigger
Duration
1Min/3Min/5Mi
n/ 3S/5S/30S/
When the Emergency Blinker option is turned on, use to set the time for how
long the display stays on after hazard lights on the vehicle stop flashing.
Display Turn Delay
30S/1Min/
3Min/5Min/
Set the length of the delay before the turn display appears on a shared
monitor.
Trigger Delay
30S/1Min/
3Min/5Min/
Set the length of time the system stays on after an actual turning event.
When set time expires the system returns to stand-by mode.
Reversing / Turning
Trigger Duration
30S/1Min/
3Min/5Min/
Set the length of time an active trigger is displayed before reverting to the
default view.
Video Output Mode
Constant/Auto
Constant: Video output is never interrupted.
Auto: Video output is only active when trigger has been activated.
G-Sensor Sensitivity
Low/Middle/
High
In the event when the bus is struck while at a standstill, the system will exit
stand-by mode and recording will start immediately. The sensitivity level
(low/middle/high) can be set to detect varying levels of vehicle contact.