INSTALLATION INSTRUCTIONS
RK 100 - RAD - ING - MAN.INST - 1311.1 - DIGITECH CS MIAH4
25
wiring by the installer
BIPOLAR SWITCH
BREAKER GENERAL
brown
yellow/green
blue
IG
power supply
230V 50Hz
L
N
2x16A
1
2
3
4
A
B
Se
Se
Ta
N
L
Ta
S
Fig. 1
3.8.2 Power supply connection
Connect the power supply to the terminal board inside the control panel as follows:
a.
Switch off the power supply at the main switch.
b.
Remove the front case panel of the boiler.
c.
Slacken the screws and remove plate A (see fig. 1).
d.
With the plate removed, connect the wires to the terminal board B as follows:
Connect the earth wire (normally coloured green/yellow) to the terminal marked with the earth symbol “ “.
Connect the neutral wire (normally coloured blue) to the terminal marked with the letter “N”.
Connect the live wire (normally coloured brown) to the terminal marked with the letter “L”.
Terminals identified by the letters: Ta
Room thermostat
Se
Outside temperature sensor
When the wires have been connected, place plate “A" back to position.