INSTALLATION INSTRUCTIONS
RK 100 - RAD - ING - MAN.INST - 1311.1 - DIGITECH CS MIAH4
14
2.9.2 LCD display icons’ key
1.
PARAMETER NUMBER INFORMATION
2.
PARAMETERS PROGRAMMING MODE ON
3.
SOLAR PCB CONNECTION INFORMATION / SOLAR
PANEL TEMPERATURE DISPLAY (d6)
4.
SOLAR PUMP ON
5.
STORAGE CYLINDER LOW LEVEL TEMPERATURE
VISUALIZATION (d7) / STORAGE CYLINDER HIGH
LEVEL TEMPERATURE VISUALIZATION (d8)
(RS
version only - with connection to a remote storage
cylinder)
6.
OUTDOOR TEMPERATURE SENSOR CONNECTED /
OUTDOOR SENSOR TEMPERATURE DISPLAY (d2)
7.
TEMPERATURE / SET POINT / PARAMETER VALUE
INFORMATION
8.
OPEN THERM COMPONENTS COMMUNICATION
CONNECTED (REMOTE CONTROL / ZONE
MANAGEMENT CONTROL BOX)
9.
WATER LOW PRESSURE INFORMATION
10.
(*) FLAME PRESENCE ON (3 POWER STEPS)
11.
D.H.W. MODE ENABLED
(RS version only - with
connection to a remote storage cylinder)
12.
RESETTABLE ERROR DISPLAY
13.
OFF MODE
14.
NOT RESETTABLE ERROR DISPLAY
15.
HEATING MODE ENABLED
10 (*) - During the boiler operation the display can show 3 different power levels according to the flame
modulation of the boiler. (see flame icon/power % images)
2.10 INFO Menu display
Press the ‘
’ INFO Button to display the boiler data.
Once pressed, the parameter number will appear on the left side of the display and the associated
parameter value will appear on the centre of the display. Use ‘
’ and ‘
’ buttons of
Heating
Temperature setting to scroll the list of available data.
Press the ‘
’ INFO button to exit the display mode.
The list of available display data is the following:
Parameter Icon
Description
d00
DHW sensor temperature
(RS version only - with connection to a remote storage
cylinder)
d01
Outdoor sensor temperature
(only with outdoor temperature sensor)
d2
Fan speed
d3
Low temperature circuit sensor
(only with Zone PCB CRAD0 connected)
d4
Heating return sensor temperature
(only with
PWM control electronic circulator
)
d5
Solar panel sensor temperature
(only with Solar PCB connected)
d6
Solar storage cylinder temperature (low level) (
only with Solar PCB connected)
d7
Solar storage cylinder temperature (high level) (
only with Solar PCB connected)
d8
Solar panel sensor temperature 2
(only with Solar PCB connected)
d9
Solar storage cylinder temperature (extra)
(only with Solar PCB connected)
4
5
6
7
9
10
11
12
13
14
15
1
2
3
8
< 33%
>33%<66%
>66%<100%
Fig. 1
Fig. 2
Содержание RK 100