INSTALLATION INSTRUCTIONS
RK 100 - RAD - ING - MAN.INST - 1311.1 - DIGITECH CS MIAH4
13
2.8 DIGITECH
®
CS Printed Circuit Board MIAH400
Technical characteristics
Adjustments for service personnel only
Standard (30/80°C) / reduced (25-45°C) central heating
temperature
Water hammer prevention function
Central Heating timer - (adjustable from 0 to 7,5 minutes)
Central Heating pump overrun timer
Domestic Hot Water pump overrun timer
(RS version only - with
connection to a remote storage cylinder)
Minimum Gas pressure setting
Maximum Heating Load
Heating output rising time
Central heating maximum and minimum Set Point adjustment
Domestic Hot Water maximum Set Point Adjustment (RS
version only - with connection to a remote storage cylinder)
Bus adjustment input 0-10V
User settings
Heating Temperature setting (30-80°C) – (25-45°C)
D.H.W. temperature setting (35-60°C)
(RS version only - with
connection to a remote storage cylinder)
Summer only mode / Winter only mode / Winter
mode selection
(if only heating the boiler is set to "heating only"
or "OFF")
Operation/Functions display
Lock-Out
Water low pressure
Temperature
display
Flame presence ON (3 power steps)
Error History display (last 5 errors)
2.9 Control panel
2.9.1 Control panel Key
(fig. 1)
1. HEATING TEMPERATURE SETTING BUTTONS
2. INFO
BUTTON:
PRESS ONCE TO DISPLAY
TEMPERATURES AND INFO (see 2.10 “INFO menu
display”). KEEP INFO BUTTON PRESSED FOR 5
SECONDS (in OFF MODE) TO DISPLAY THE LAST 5
ERRORS.
3. MODE SELECTION BUTTON
SUMMER ONLY /
WINTER ONLY / SUMMER-WINTER / OFF.
4. RESET
BUTTON:
ERROR RESET – FLUE TEST
FUNCTION ACTIVATION (CHIMNEY-SWEEPER -
KEEP IT PRESSED FOR 7 SECONDS).
5. DOMESTIC HOT WATER TEMPERATURE SETTING
BUTTONS
(RS version only - with connection to a
remote storage cylinder)
.
KEEP BUTTONS ‘+’ AND
‘-‘ PRESSED FOR 5 SECONDS TO ACTIVATE THE
DISPLAY BACKLIT MODE FOR A CONTINUOUS PERIOD OF 10 MINUTES.
6.
TERMINAL BLOCK FOR EXTERNAL WIRING.
7.
LCD DISPLAY.
Fig. 1
To switch the boiler OFF,
press
INFO button,
the symbol
appears on
the display. The central
heating frost protection
system and the circulating
pump inactivity protection
functions remain enabled.
If the boiler was previously
ON, it is switched OFF and the
fan overrun and pump
overrun functions are
enabled.
S
7
1
2 3
4
5
6