Instruction manual Wav WaveGuide Server
Data logging
(processing option only)
.
Data logging is an option. The WaveGuide Server is equipped with
an USB connector. Due to the narrow space the connector has a 90
degrees adapter in it.
A USB hard disk or a USB stick can be connected.
Therefore for safe data storage an UPS and a good quality USB drive is needed.
The USB disk that is connected should not be formatted by the Windows NTFS system as this format is not
supported by other operating systems. The WaveGuide Server can cope with FAT32 , Ext2 and Ext3. The majority
of usb disks and usb flash drives are delivered with FAT32.
Mount the drive.
The system does not couple the drive automatically. This should be done via the push buttons at
the WaveGuide Server ( data logger menu mount system)
Unmount/ remove safely
. The USB disk can be removed safely by using the push buttons at the WaveGuide
Server. Go to the Storage menu via button 1 and then via button 2 to safely remove.
The data logger page in the user interface gives access to the stored data.
Version 4.1
20 of 30
Oct 2013
Fig. 21: The data logger access page.
Without extra attention the USB storage is not a safe method to archive data.
The WaveGuide System will automatically start after a power failure. A USB disk however can be
damaged by a power failure.
Fig. 20: USB connector.