Instruction manual Wav WaveGuide Server
-0004
A+9999 (=error condition)
FGTI format
The Belgium government (FGTI) requested one string with all required information (para spectrum) per
processing interval. The format is like the Radac format only with all parameters separated by semi colon (;). Also
the 51 spectrum values are in this message. The “NaN” string is replaced by a “-9999” string.
time=1159898219628;sensor=radcan;H1/3=0.101608045cm;Hm0=0.070818946cm;Czz10=0.0,5.086943
2E-5,1.3970293E-4,4.7124052E-4,7.1615004E-4,7.975558E-4,7.6214876E-4,7.1647903E-
4,7.6107396E-4,6.847791E-4,6.6441507E-4,4.567583E-4,7.3393347E-4,8.3342794E-4,7.177321E-
4,8.320104E-4,9.631133E-4,4.7024636E-4,5.479116E-4,7.0798665E-4,7.973897E-4,8.964213E-
4,0.0010354978,5.15721E-4,8.0113555E-4,8.009798E-4,8.0272334E-4,8.0752687E-4,6.5126666E-
4,8.172201E-4,5.1516114E-4,6.2683446E-4,5.63858E-4,3.5074513E-4,6.5980386E-4,5.53472E-
4,7.269641E-4,6.289437E-4,6.156702E-4,5.8503065E-4,6.2185246E-4,5.5198127E-4,4.41777E-
4,2.7770927E-4,3.32
After successful authorization, the changed settings will be stored and a reboot dialog will appear. The settings
will not be effective until the WaveGuide Server is rebooted.
Version 4.1
17 of 30
Oct 2013