R-sensors LLC
Bldg. 1, 4, Likhachevsky proezd, Dolgoprudny, 141701, Russia
+7 (498) 744-69-95,
NDAS-N. User Manual.
71
19. Technical specifications
19.1
Electrical parameters
Supply voltage
12-48 V DC
(7.5-60 V permissible)
Power consumption
Minimal power consumption
8
Typical average
No more than 1.5 W
1.6-3,0 W
Maximum consumption
9
No more than 12.95 W
Supply voltage via USB
10
4.5-5.5
V
19.2
Mechanical parameters
Connector types
DH-20-C07SX-03-401 is a power and RS-485 interface
connector;
LP-24-J/RJ45/213/SX-43-401 is the RJ-45 type connector
for a wired Ethernet;
SMA-F is an antenna connection for GPS/Wi-Fi/3G/LTE –
1 to 3
11
pcs;
micro-USB is an input for a wired USB connection and
data reading;
YU-USB2-JSX is a USB-A input for connecting external
USB drives and CME-ND digital sensors;
DH-24-J19SX-03-401 are inputs of auxilliary ADC and
outputs of signal relay;
DH-20-C12SX-03-401 are inputs of the main ADC and
outputs for active sensors power – 2 pcs.
Weight
1.5-1.8 kg (3.3-4.0 lbs) depending on the internal modules
composition and additional connectors
8
The average consumption of the Module during self-contained recording with no Ethernet, Wi-Fi, 3G or supply to the
sensors activated.
9
Maximum overall system consumption including peripherals.
10
Only the digital subsystem is powered, ADC included.
11
Additional connectors are installed when using Wi-Fi and 3G modem.