NDAS-N. User Manual.
42
Fig. 8.3. SeedLink server module. Station settings
For example, when entering the data as given in the screenshot, the first channel of the data logger
will have the full code in the SeedLink system as
RU.ND01.00.DNZ.D
(where the latter
D
means the
Data type).
The sampling rate of the NJSP incoming signal must match the
Sample rate
parameter. That means for correct operation it is necessary to set the same sampling
rate in two settings – in the parameters of the signal source (data logger) and in the
parameters of the SeedLink module.
8.4. Auxiliary channels
The
NJSP
protocol transmits the auxiliary data such as the data logger coordinates, temperature,
supply voltage, and other telemetry data. In the SeedLink Server module this data falls into a separate
stream that has an
AU
code as signals with a sampling rate of 1/10 Hz. The
location code
parameter is
set by default as
00
.