Page
35
of
86
USER
ACTIVE
(USR
A
ON
SCREEN)
–
At
the
time
of
patient
testing,
the
user
has
the
ability
to
deselect
the
test.
6.
Press
the
key
to
save
changes.
QC
Tests
With
Test
Settings
Activated
Any
test
which
the
Supervisor
has
set
to
ACTIVE,
USER
ACTIVE
or
USER
INACTIVE
will
run
on
the
QC
Sample
panel.
The
meter
will
display
and
the
test’s
QC
sample
result
and
update
the
QC
Sample
timer
for
the
test.
If
the
Supervisor
has
set
the
test
to
INACTIVE
,
the
test
will
have
the
QC
Sample
turned
OFF.
The
QC
Sample
result
won’t
show
for
that
test
and
the
QC
Sample
timer
won’t
be
updated
for
it.
If
the
Supervisor
changes
the
test
from
INACTIVE
to
ACTIVE
,
to
USER
ACTIVE
or
to
USER
INACTIVE
that
test
may
be
out
of
QC
Sample
date.
As
always
for
a
test
with
an
expired
QC
Sample,
a
passing
QC
Sample
test
will
need
to
run
before
a
patient
sample
can
report
a
result
for
that
test.
QC
Parameters
The
QC
Parameters
menu
provides
the
user
the
options
for
determining
what
the
maximum
frequency
is
for
running
the
QC
Device
and
QC
Sample,
whether
1
or
2
levels
of
control
are
required
for
the
QC
Sample,
and
whether
the
allowed
QC
Sample
Range
of
quantitative
tests
is
2
or
3
standard
deviations.
QC
Device
Frequency
The
QC
DEVICE
FREQUENCY
setting
determines
the
maximum
interval
between
QC
Device
tests
that
a
user
is
allowed
to
run
patient
tests.
When
the
interval
has
lapsed,
all
users
are
locked
out
of
the
Run
Test
menu
until
a
QC
Device
has
been
successfully
run.
It
is
recommended
that
the
QC
Device
be
run
daily
when
performing
patient
testing.
1.
From
the
list
of
programmable
parameters,
choose
QC
PARAMETERS
using
the
keys.
2.
Press
the
key.
3.
Use
the
keys
to
select
the
information
to
the
right
of
QC
DEVICE
FREQ
.
4.
Using
the
keys,
select
one
of
these
options:
NONE,
8
HOURS,
DAILY,
WEEKLY,
MONTHLY
.
5.
Press
the
key
to
save
changes.
QC
Sample
Frequency
The
QC
SAMPLE
FREQUENCY
setting
determines
the
maximum
interval
between
QC
Sample
tests
that
a
user
is
allowed
to
run
patient
tests
on
a
particular
device
lot
number.
When
the
interval
has
lapsed,
all
users
are
locked
out
of
the
RUN
PATIENT
TEST
menu
until
a
QC
Sample
has
been
successfully
run.
To
view
when
a
particular
device
lot’s
QC
Sample
will
expire,
use
the
RECALL
REAGENT
LOTS
–
QC
feature.
It
is
recommended
that
the
QC
Sample
be
run
with
every
new
shipment,
new
lot
or
monthly,
whichever
is
less
when
performing
patient
testing.
NOTE:
When
the
analyte
is
deselected,
the
value
is
not
calculated
nor
stored
Main
Menu
Set
Parameters
QC
Parameters
Содержание Triage MeterPro