UMTS/HSPA+ Module Series
UG89 Hardware Design
UG89_Hardware_Design 55 / 73
5.7. Electrostatic Discharge
The module is not protected against electrostatics discharge (ESD) in general. Consequently, it is subject
to ESD handling precautions that typically apply to ESD sensitive components. Proper ESD handling and
packaging procedures must be applied throughout the processing, handling, and operation of any
application that incorporates the module.
The following table shows the module electrostatics discharge characteristics.
Table 30: Electrostatics Discharge Characteristics (Temperature=25 ºC, Humidity=45%)
GSM850
-109.5dBm
NA
NA
-102.0dBm
EGSM900
-109.5dBm
NA
NA
-102.0dBm
DCS1800
-108.5dBm
NA
NA
-102.0dBm
PCS1900
-108dBm
NA
NA
-102.0dBm
WCDMA B1
-109.5dBm
NA
NA
-106.7dBm
WCDMA B2
-109.5dBm
NA
NA
-104.7dBm
WCDMA B5
-110dBm
NA
NA
-104.7dBm
WCDMA B6
-111dBm
NA
NA
-106.7dBm
WCDMA B8
-110dBm
NA
NA
-103.7dBm
Tested Points
Contact Discharge
Air Discharge
Unit
VBAT, GND
±8
±12
kV
All Antenna Interfaces
±8
±12
kV
Other Interfaces
±0.5
±1
kV