98
Troubleshooting the SAN
4
When you are finished viewing the data, select
OK
.
5
Environmental data ranges may vary from appliance type to appliance type.
Using Health Check
Health Check
allows you to determine periodically the operational state of SNC connections to the
interfaces it controls. When the
Health Check
is disabled, the SNC performs no periodic checks beyond
monitoring environmental status lines, which indicate power supply and temperature conditions. The
Health
Check
function posts SNMP traps when required to convey status information to the user interface.
Performing Health Check
The
Perform Health Check
command requests an immediate health check at the current level specified.
This check is performed regardless of the Health Check Interval setting.
1
Right-click an appliance in the navigation panel or the graphical panel.
2
Select the
Health Check
menu, then select
Perform Health Check
.
Unless you have reset the level, Health Check is performed at the
Interface Test
level. See
Table 3
.
A message posts in the
Status/Message area
if the test is successful, For example,
Successful Health
Check
is displayed in this area.
Configuring Health Check
You can configure
Health Check
settings.
1
Right-click an appliance in the navigation panel or the graphical panel.
2
Select the
Health Check
menu, then select
Health Check Settings
.
The default tab is the
Level
tab. See
Table 3
. Options on this tab allow you to choose how thorough the
health check will be when it is performed.
3
When you are satisfied with the level, select
OK
.
If you decide not to change the health check level settings, select
Cancel
.
Table 3
Health Check Levels
Level Name
Functionality
None
Health check disabled
Basic Function
Check power supply and temperature status
Interface Test
Everything from Basic level in addition to checking all interfaces
Device Test
Everything from Interface Test level, in addition to performing a Device
Inquiry on each target device
Device Ready
Everything from Device Test level, in addition to performing a Test Unit
Ready on each target device (non-removable media only)
Note
Health check levels in AMC are not identical to the health check levels used by
the library management clients for the i-platform libraries.
Содержание Scalar i2000
Страница 1: ...User sGuide ADICManagementConsole 4 4...
Страница 8: ...viii Contents...
Страница 26: ...18 Getting Started...
Страница 30: ...22 Frequently Asked Questions...