![Qorivva MPC5 Series Скачать руководство пользователя страница 148](http://html1.mh-extra.com/html/qorivva/mpc5-series/mpc5-series_manual_3255432148.webp)
Qorivva MPC5xxx/SPC5xx Debugger and NEXUS Trace
148
©1989-2021 Lauterbach GmbH
TrOnchip.EXTernal
Enable trace trigger input of NEXUS adapter
The NEXUS adapter provides an additional (active-high) trigger input to stop the trace recording. The input
is labeled “IN” or “IN0” on LA-7610 and “IX0” on LA-7630 adapters. The input channel recognizes signals
with a minimum pulse length of 20 ns.
The recorded value of the input channel can be observed in the Trigger.0 row of the
window.
The Complex Trigger Unit (CTU) supports the input channel level as condition
IN
.
TrOnchip.Out0
Select OUT0 pin signal source
Selects the signal source for the OUT0 pin of the NEXUS connector. On LA-7630 adapters, the signal is
labeled “Ox0”.
WDTC
source can be used to activate the OUT0 output in parallel to the
TD/WDTE
pin. It can control an
external WDTC (or something else). It is a second output, controlled by
.
Format:
TrOnchip.EXTernal
<source>
<source>
:
OFF
|
IN0
;Show program flow and input channel
Trace.List DEFault Trigger.0
Format:
TrOnchip.Out0
<source>
<source>
:
Trigger
|
Evto
|
WDTC
Trigger
Trigger output of CTU (OUT.A)
Evto
Directly driven by EVTO input
WDTC
Watchdog Timer Control