8–Configuring FCoE in a Linux Environment
Using the QLogic Linux Utilities
FE0254601-00 A
8-53
The Set Device Command Timeout utility can set the timeout value for target
devices on a selected host, or it can set a common value for all devices on all
hosts. This utility sets a timeout value for each target port and applies to all LUNs
that are visible through that target port. This utility does not apply to targets that
are visible through QLogic adapter virtual ports.
Package Contents
Table 8-22
describes the files in the Set Device Command Timeout utility
package.
Using the Utility
This utility has a line command interface and a menu interface.
Command Line Interface
To display the timeout values for devices connected to a specified host ID, issue
the following command:
#
./ql-set-cmd-timeout.sh
<HOST #>
To display the timeout values for devices connected to a specified target and host
ID, issue the following command:
#
./ql-set-cmd-timeout.sh
<HOST #> <TARGET #>
To set the timeout values for devices connected to a specified target and host ID,
issue the following command:
#
./ql-set-cmd-timeout.sh
<HOST #> <TARGET #> <TIMEOUT #>
If you omit all command options, the utility displays the timeout values on devices
connected to the all QLogic Converged Network Adapter ports.
Table 8-22. Set Device Command Timeout Utility Package Files
File
Description
COPYING
GNU general public license that describes rights to
copy, distribute, and use the open source content in
this Linux tool
ql-set-cmd-timeout.sh
Script file that sets the timeout on the devices con-
nected to the QLogic Converged Network Adapter
README.ql-set-cmd-timeout.txt
Readme file
revision.qlsetcmdtimeout.txt
Text file that explains the changes that are new in
this version of the package
Содержание QConvergeConsole CLI 8100 Series
Страница 1: ...FE0254601 00 A User s Guide Converged Network Adapter 8100 Series...
Страница 18: ...xviii FE0254601 00 A User s Guide Converged Network Adapter 8100 Series Adapters...
Страница 26: ...Preface Legal Notices xxvi FE0254601 00 A...
Страница 30: ...Quick Start Additional Resources xxx FE0254601 00 A...
Страница 98: ...3 Installation in a Windows Environment Installing Management Tools 3 48 FE0254601 00 A...
Страница 254: ...7 Configuring FCoE in a Windows Environment Boot from SAN 7 26 FE0254601 00 A...
Страница 330: ...9 Offline Utilities EFIUTIL 9 18 FE0254601 00 A...
Страница 338: ...B Cisco Nexus 5000 Series Switch Configuration Verify that the Adapter Is Logged into the Switch B 6 FE0254601 00 A...
Страница 346: ...C Brocade CEE FCoE Switch Blade Configuration Verify that the Adapter is Logged into the Switch C 8 FE0254601 00 A...
Страница 347: ......