6–Configuring NIC Functionality in the Converged Network Adapter
Configuring the NIC in a Linux Environment
FE0254601-00 A
6-43
arp_ip_target
IP address
Specifies the IP addresses to
use as ARP monitoring peers
when arp_interval is > 0.
These are the targets of the
ARP request that are sent to
determine the health of the
link to the targets.
None
Up to 16 IP addresses
(comma separated)
downdelay
milliseconds Specifies the time to wait
before disabling a slave after
a link failure has been
detected. This option is valid
only for the miimon link moni-
tor. The downdelay value
should be a multiple of the mii-
mon value; if not, it will be
rounded down to the nearest
multiple
0
32767
updelay
milliseconds Specifies the time to wait
before enabling a slave after a
link recovery has been
detected. This option is valid
only for the miimon link moni-
tor. The updelay value should
be a multiple of the miimon
value; if not, it will be rounded
down to the nearest multiple.
0
32767
max_bonds
Integer
Specifies the number of bond-
ing devices to create for this
instance of the bonding driver.
For example, if
max_bonds
is
3, and the bonding driver is
not already loaded, then
bond0
,
bond1
and
bond2
are
created.
1
NA
Table 6-4. Linux Bonding Driver Parameters (Continued)
Parameter
Name
Unit
Description
Default
Value
Allowed Values
Содержание QConvergeConsole CLI 8100 Series
Страница 1: ...FE0254601 00 A User s Guide Converged Network Adapter 8100 Series...
Страница 18: ...xviii FE0254601 00 A User s Guide Converged Network Adapter 8100 Series Adapters...
Страница 26: ...Preface Legal Notices xxvi FE0254601 00 A...
Страница 30: ...Quick Start Additional Resources xxx FE0254601 00 A...
Страница 98: ...3 Installation in a Windows Environment Installing Management Tools 3 48 FE0254601 00 A...
Страница 254: ...7 Configuring FCoE in a Windows Environment Boot from SAN 7 26 FE0254601 00 A...
Страница 330: ...9 Offline Utilities EFIUTIL 9 18 FE0254601 00 A...
Страница 338: ...B Cisco Nexus 5000 Series Switch Configuration Verify that the Adapter Is Logged into the Switch B 6 FE0254601 00 A...
Страница 346: ...C Brocade CEE FCoE Switch Blade Configuration Verify that the Adapter is Logged into the Switch C 8 FE0254601 00 A...
Страница 347: ......