8–Configuring FCoE in a Linux Environment
N_Port ID Virtualization
8-28
FE0254601-00 A
To disable a virtual port, issue the following command, where
X
is the port SCSI
host ID:
#
echo 1 > /sys/class/scsi_host/hostX/vport_disable
To verify that the virtual adapter port has been deleted:
Confirm that the
sysfs
entry for the virtual port has been removed from
/sys/class/scsi_host/
.
Confirm that the virtual port is no longer logged into the FCoE switch by
inspecting its Fibre Channel name server database. For information about
examining the name server database, refer to the switch documentation.
Differentiating Virtual Ports from Physical Ports in sysfs
Virtual ports and physical ports have different sets of sysfs parameters. You can
distinguish a virtual port from a physical port by listing the port parameters in
sysfs, and then comparing the display to the unique parameter lists in
Table 8-8
.
Figure 8-11
shows an example the sysfs adapter port parameter lists for a
physical port (left) and a virtual port (right). The distinguishing parameters are
indicated by green and red arrows.
Table 8-8. Unique Physical and Virtual Port sysfs Parameters
Unique Physical Port sysfs
Parameters
Unique Virtual Port sysfs
Parameters
max_npiv_vports
npiv_vports_inuse
vport_create
vport_delete
node_name
port_name
vport_disable
vport_id
vport_last_state
vport_state
Содержание QConvergeConsole CLI 8100 Series
Страница 1: ...FE0254601 00 A User s Guide Converged Network Adapter 8100 Series...
Страница 18: ...xviii FE0254601 00 A User s Guide Converged Network Adapter 8100 Series Adapters...
Страница 26: ...Preface Legal Notices xxvi FE0254601 00 A...
Страница 30: ...Quick Start Additional Resources xxx FE0254601 00 A...
Страница 98: ...3 Installation in a Windows Environment Installing Management Tools 3 48 FE0254601 00 A...
Страница 254: ...7 Configuring FCoE in a Windows Environment Boot from SAN 7 26 FE0254601 00 A...
Страница 330: ...9 Offline Utilities EFIUTIL 9 18 FE0254601 00 A...
Страница 338: ...B Cisco Nexus 5000 Series Switch Configuration Verify that the Adapter Is Logged into the Switch B 6 FE0254601 00 A...
Страница 346: ...C Brocade CEE FCoE Switch Blade Configuration Verify that the Adapter is Logged into the Switch C 8 FE0254601 00 A...
Страница 347: ......