4–Installation in a Linux Environment
Management Tool Installation
FE0254601-00 A
4-35
Installing and Launching the QLogic Linux Tools
The QLogic Linux utilities manage the adapter FCoE function. The QLogic Linux
tools package (
Linux-Tools-
yyyymmdd-x
.tgz
) is a compressed file that
contains the utility packages described in
Table 4-1
.
To install and launch the QLogic Linux utilities on the RHEL 5 host:
1.
Extract the component files from the
Linux-Tools-
yyyymmdd-x
.tgz
file
by typing the following command:
#
tar –xvzf Linux-Tools-
yyyymmdd
-
x
.tgz
2.
Extract the utilities, readme documents, and release notes from the
corresponding compressed files by typing the following commands:
#
tar -xvzf ql-dynamic-tgt-lun-disc-
x
.
xx
.tgz
#
tar -xvzf ql-hba-collect-
x
.
x
.tgz
#
tar -xvzf ql-hba-snapshot-
x
.
xx
.tgz
#
tar -xvzf ql-lun-state-online-
x
.
x
.tgz
#
tar -xvzf ql-set-cmd-timeout-
x
.
x
.tgz
3.
For each utility, change to the directory listed in
Table 4-2
, and enter the
corresponding command to launch the utility.
Table 4-1. QLogic Linux Utilities
Utility File
Description
ql-dynamic-tgt-lun-disc-
x
.
xx
.tgz
Scans for newly added LUNs
ql-hba-collect-
x
.
x
.tgz
Gathers troubleshooting information on a variety of
Linux hosts
ql-hba-snapshot-
x
.
xx
.tgz
Uses sysfs to display details about the QLogic Fibre
Channel adapter that is installed in the server
ql-lun-state-online-
x
.
x
.tgz
Changes the state of LUNs connected to a QLogic
Fibre Channel adapter from offline to online
ql-set-cmd-timeout-
x
.
x
.tgz
Sets the timeout on the devices connected to the
QLogic Fibre Channel adapter
Table 4-2. QLogic Linux Utility Directories and Commands
Directory
Command
ql-dynamic-tgt-lun-disc-
x
.
xx
/
./ql-dynamic-tgt-lun-disc.sh –i
ql-hba-collect-
x
.
x
/
./ql-hba-collect.sh
Содержание QConvergeConsole CLI 8100 Series
Страница 1: ...FE0254601 00 A User s Guide Converged Network Adapter 8100 Series...
Страница 18: ...xviii FE0254601 00 A User s Guide Converged Network Adapter 8100 Series Adapters...
Страница 26: ...Preface Legal Notices xxvi FE0254601 00 A...
Страница 30: ...Quick Start Additional Resources xxx FE0254601 00 A...
Страница 98: ...3 Installation in a Windows Environment Installing Management Tools 3 48 FE0254601 00 A...
Страница 254: ...7 Configuring FCoE in a Windows Environment Boot from SAN 7 26 FE0254601 00 A...
Страница 330: ...9 Offline Utilities EFIUTIL 9 18 FE0254601 00 A...
Страница 338: ...B Cisco Nexus 5000 Series Switch Configuration Verify that the Adapter Is Logged into the Switch B 6 FE0254601 00 A...
Страница 346: ...C Brocade CEE FCoE Switch Blade Configuration Verify that the Adapter is Logged into the Switch C 8 FE0254601 00 A...
Страница 347: ......