Checking Controller (continued)
/
Verificar el controlador (continuación)
START
STOP
RESET
START
STOP
RESET
EN
9
Turn the control switch to
<RESET> (
) to clear the
error.
10
Verify the control displays
“0”.
11
Turn the control switch to
<START> (
).
12
Ensure the conveyor belt is
running.
ES Girar el controlador para reiniciart (
) para borrar el error
Verificar que el controlador indique 0
Girar el controlador para iniciar ( )
Asegurarse de que la cinta trans-
portadora esté andando
If the conveyor does not start, the clear plastic guards may not be making contact with the sensors; or the emergency stop could be activated. Check all of the clear
plastic guards for proper placement and verify that all of the twist nuts are in the horizontal, locked position. Also, ensure the emergency stop is deactivated.
Si la cinta transportadora no comienza a funcionar, es posible que las protecciones de plástico no estén haciendo contacto con los sensores o que la parada de
emergencia esté activada. Verificar que todas las protecciones estén colocadas correctamente y asegurarse de que todas las tuercas de rosca estén en la posición de
bloqueo (horizontal). Asegurarse también de que la parada de emergencia esté desactivada.
Repeat this procedure for the second conveyor.
Repetir este procedimiento para la segunda cinta transportadora.
If problems occur, please refer to the “Troubleshooting” section on page 24 of this manual for corrective actions.
Si ocurren problemas, consultar la sección Resolución de problemas en este manual (página 24) para corregir el problema.