_____________________________________________________________________________________________
Q3
ENERGIE
Installation and operating instructions Q
X
³ series
37/109
Version 1.0, Stand 27.04.2015
Installation and operating instructions
Q
X
³ series
AC mains plug Q
X
³10000-18000:
Pos
Meaning
A
Cable gland
B
AC plug connector housing
C
4 x screws for the contact insert
D
Contact insert
E
Contact insert (opened)
NOTE
The cable gland seals the housing against
humidity and relieves the cable from
mechanical stressing.
AC connections work steps:
No.
Action
1
Observe the technical connection requirements (TAB) of the power supply company!
2
Check the supply voltage and compare it with the inverter type plate.
3
Switch off the DC switch disconnecter on the inverter
4
Prepare the AC grid cable as shown
5
Connect the AC grid cable and / AC power plug as shown (observe and verify the
rotating field).
6
Connect the AC power plug to the inverter and screw in place.
7
Check that all cables are firmly attached.