9.3 Measuring Voltage to Compressor
9.3.1
Remove the Front Panel (section 8.10 ).
With the Compressor running:
9.3.2
Locate the Compressor
power connector.
9.3.3
Use a Voltmeter to measure
the voltage between the
BLACK and WHITE wires:
9.3.3.1
Place the Voltmeter
probes in the openings
in the power connector.
The voltage should measure:
•
110 - 125 VAC
for the P4200W2 & P4200W2LP models.
•
220 - 230 VAC
for the P4202W2, P4202W2LP & P4202W2H models.
9.3.4
Reinstall the Front Panel (section 8.10 ).
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.