PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 69 of 113
P012308 - Rev. E
9.4 Measuring Voltage at the Power Line Filter
9.4.1
Remove the Top Cover (section 8.11 ).
9.4.2
Locate the Power Line
Filter inside the Top Section
of the air dryer.
9.4.3
Use a Voltmeter to measure
the voltage:
9.4.3.1
Place the probes
between the Power Line
Filter and terminal
insulation so that they
touch the metal
contacts.
The voltage should measure:
•
110 - 125 VAC
for the P4200W2 & P4200W2LP models.
•
220 - 230 VAC
for the P4202W2, P4202W2LP & P4202W2H models.
If any of the voltage measurements are different than indicated above, the Power
Line Filter is defective and should be replaced. See sections 11.1 for part detail
and 11.7 for ordering information.
9.4.4
Reinstall the Top Cover (section 8.11 ).
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.