PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 70 of 113
P012308 - Rev. E
9.5 Measuring Incoming Voltage
9.5.1
Remove the Top Cover (section 8.11 ).
9.5.2
Locate the Power IEC
Connector inside the Top
Section of the air dryer.
9.5.3
Use a Voltmeter to measure
the voltage:
9.5.3.1
Place the probes
between the IEC
Connector and terminal
insulation so that they
touch the metal
contacts.
The voltage should measure:
•
110 - 125 VAC
for the P4200W2 & P4200W2LP models.
•
220 - 230 VAC
for the P4202W2, P4202W2LP & P4202W2H models.
If the incoming voltage measures less than indicated above, it is recommended
that steps be taken at your facility to increase the incoming power to the
recommended levels.
9.5.4
Reinstall the Top Cover (section 8.11 ).
WARNING!
Extreme care should be exercised to avoid contact with live
electrical circuits.
It is highly recommended that you remove all
jewelry before performing any procedures.