PUREGAS, LLC
P4200W2 Series Air Dryer User’s Guide
Page 31 of 113
P012308 - Rev. E
8.5.5 High Flow Rate Alarm –
Occurs when the Flow Rate (
FLOW
) rises above the alarm threshold for
more than one (1) minute. (Default setting is 74.0 SCMD)
This screen will be displayed,
showing the Date and Time that
the alarm occurred.
8.5.5.1
Press the Info (
) Button
to see the detail of the
alarm.
See section 13.9 for troubleshooting information.
8.5.6 High Duty Cycle Alarm –
Occurs when the Duty Cycle (
DUTY CYCLE
) exceeds the alarm threshold
during the Air Tank pressurization cycle. (Default setting is 70%)
This screen will be displayed,
showing the Date and Time that
the alarm occurred.
8.5.6.1
Press the Info (
) Button
to see the detail of the
alarm.
See section 13.17 for troubleshooting information.