9.7 Testing Consistent Heatless Dryer Cycling
9.7.1
Remove the Front Panel (section 8.10 ).
With the Compressor running
:
9.7.2
Disconnect the purge tubes
from the Heatless Dryer.
9.7.3
Place your hand beneath the
purge fittings to feel for
purging air. Air should:
•
Purge from Tower 1 side
•
Purge from Tower 2 side
30 Seconds
later
•
Purge from Tower 1 side
30 Seconds
later
•
…and so on.
9.7.4
Re-connect the purge tubes
to the Heatless Dryer.
9.7.5
Reinstall the Front Panel
(section 8.10 ).
If the Heatless Dryer is not cycling consistently as described, see section 13.13