EDDYTHERM control panel
Brief description of operating
m
odes and functions
Temperature hold
The workpiece is heated to the set temperature and held at that temperature until it is needed. It is automatically
demagnetized before it is removed.
Temperature shutoff
The workpiece is heated to the set temperature and then demagnetized. An acoustic signal indicates completion of
the heating process.
Timed shutoff
The workpiece is heated for the set duration and then demagnetized. An acoustic signal indicates completion of the
heating process. This program must be selected when heating without the temperature probe or heating large or
heavy workpieces that heat very slowly.
Reduced-power heating option
This function makes it possible to run the powerful heater at full power or at reduced power in 20% steps. This
ensures that small workpieces are not overheated or heated too quickly (an important consideration for C1/C2
bearings).
Demagnetization
Workpieces may be demagnetized at any time without being heated first.
Program interruption
If the heating cycle in progress is aborted by pressing the STOP key, the demagnetization process takes place
automatically.
The selected operating mode or function is indicated by the corresponding indicator LED.