Event Log Error Messages
Tsunami MP-8100 Reference Manual
79
ERROR
tftp: Read on the new
firmware failed
Firmware file not readable;
hence invalid.
Check the image file and
the license. Contact
customer support if the
problem persists.
ERROR
Image size not equal to bytes
read
Download operation is not
successful.
Check network
configuration and retry.
ERROR
Image flashing failed
Not able to save the image.
Retry after reboot.
INFO
tftp: System is going to reboot
Image file successfully written to
flash after download and system
is going to reboot and come up
with the new image.
NONE
ERROR
Image ID Does not Match
Image ID does not match with
the firmware ID in the device.
Check image file and
license before retrying.
ERROR
Unable to create ‘image name’
file
Unable to create a file with the
given image file name.
Reboot the device and
retry.
INFO
‘image name’ File Write Error
Unable to write the image file
obtained into flash
.
Reboot the device and
retry.
ERROR
Unable to Close the ‘image file’
File
Unable to write the image file
obtained into flash.
Reboot the device and
retry.
ERROR
Error in Flash write
Unable to write the image file
obtained into flash.
Reboot the device and
retry.
ERROR
TFTP operation in progress...
Another operation is selected
while TFTP operation was in
progress.
Check your configuration
and retry.
ERROR
We couldn't fork a child
process, may be because of
lack of memory
TFTP operation failure.
Reboot the device and
retry.
ERROR
Couldn’t create the status file
TFTP operation failure.
Reboot the device and
retry.
ERROR
Invalid Config ID returned by
Flash module
The current configuration file
may belong to an older build.
While updating the
image, it is advised to
remove the current
configuration.
ERROR
File Name given is not valid [
~`!$^&*()=|\\{}[];\"'<>? ]
should be avoided in filenames
Avoid any special characters
while providing file name.
Check the file name.
Error Type
Message
Description
Corrective Action