Command Line Interface
Tsunami MP-8100 Reference Manual
35
•
Deny IPX LSP
•
Deny IP Broadcasts
•
Deny IP Multicasts
The device can filter these protocols in the wireless interface to?Ethernet direction, the Ethernet?to?wireless direction, or in
both directions. You can configure the following advanced filtering options:
Worp Intracell
The following commands are used to “enable” WORP Intracell Configuration and it is configurable only in BSU with bridge
mode.
Group Table
The following commands are used to “enable” group table configuration and it is configurable only in BSU with bridge
mode.
System Name (config-filter)#advanced
System Name(config-filter-advanced)# rowedit 1 direction ethernet2wireless
System Name(config-filter-advanced)# rowedit 1 protocol-name Deny IPX RIP
System Name(config-filter-advanced)# rowedit 1 entry-status enable
System Name(config-filter-advanced)#exit
System Name(config-filter)#exit
System Name(config)#exit
System Name# show filtering advanced
// ADVANCED FILTER TABLE CONFIGURATION
INDEX 1
Protocol Name : Deny IPX RIP
Direction : ethernet2wireless
Entry Status : enable
INDEX 2
Protocol Name : Deny IPX SAP
Direction : both
Entry Status : disable
INDEX 3
Protocol Name : Deny IPX LSP
Direction : both
Entry Status : disable
INDEX 4
Protocol Name : Deny IP Broadcasts
Direction : both
Entry Status : disable
INDEX 5
Protocol Name : Deny IP Multicasts
Direction : both
Entry Status : disable
System Name (config-filter)#worp-intracell
System Name(config-filter-intracell)# intracell-status enable
System Name(config-filter-intracell)#exit
System Name(config-filter)#exit
System Name(config)#exit
System Name(config)#exit
System Name# show filtering worp-intracell intracell-status
Intra cell status : enable