External storage module:
PVD-U (collection pan: PE)
Control housing:
PPE GF10
Membrane keypad:
Polyester PET membrane
Pump housing:
PPE, fibreglass-reinforced
Pump liquid ends:
PP, PVDF
Power supply
Data
Value Unit
Nominal voltage, ± 10 %
230 or 115 V
Mains supply frequency
50 / 60 Hz
Socket fuse
16 A
Fuses
Description
Type
Supplied ...
Terminals
Part no.
F1
0.4 ATT
Control
XP
712060
F2
3.15 ATT
pumps, sole‐
noid valves
712069
Micro fuse 5 x 20 mm
Alarm relay (XR2:2 and XR2:1):
Type of contact: N/C or N/O (adjustable via Menu)
Load capacity: 250 V AC / 3 A / 100 VA
Warning relay (XR1:1 and XR2:1):
Type of contact: N/O
Load capacity: 250 V AC / 3 A / 100 VA
Operating indicator relay (XR1:2 and XR2:1):
Type of contact: N/O
Load capacity: 250 V AC / 3 A / 100 VA
Technical data, electrical
System
Control
Outputs
Switching outputs
Technical data CDLb
55