4.
Testing the sensors' hydraulic installation: Adjust the flow
using the shut-off valve to 20... 60 l/h
ð
Check whether the threaded connectors on the in-line
probe housing are tight.
If there is already sample water in the in-line probe
housing
Slowly lower the sensor into the in-line probe
housing. Otherwise the diaphragm of the sensor is
overstretched and the sensor delivers incorrect
values.
1.
Remove the securing bolt (1) using a 35 mm ring spanner
2.
Fit the sensor with electrolyte as described in the sensor
operating instructions
3.
Push the O-ring (4), then the assembly washer (5) onto the
sensor (3) from below
ð
The components must lie against the clamp disc (2)
4.
Then push the securing bolt (1) from above onto the sensor
(3)
5.
Carefully push the sensor (3) into the module (6) of the in-line
probe housing
6.
Tighten the securing bolt (1) using a 35 mm ring spanner
7.
Testing the sensors' hydraulic installation: Adjust the flow
using the shut-off valve to 20... 60 l/h
ð
Check whether the threaded connectors on the in-line
probe housing are tight.
6.3 Electrical installation
The controller is used to switch and provide the
power supply to the alpha and Beta metering
pumps. The sockets are already installed on the
mounting plate.
Chlorine sensor installation
A0968
1.
2.
3.
4.
5.
6.
Fig. 16: Assembling the sensor
Assembly
27