Fig. 13: Multifunctional switch (1) on [EXTERNAL]
NOTICE!
Maximum permissible operating pressure when
using a chlorine sensor
Limit the pressure on the measured water extrac‐
tion point to a maximum of 1 bar (at 30 °C) using a
pressure reducer. otherwise the maximum permis‐
sible operating pressure of the chlorine sensor will
be exceeded.
Do not allow a back pressure of more than 1 bar
(at 30 °C) to build up at the outlet, otherwise the
maximum permissible operating pressure of the
chlorine sensor will be exceeded.
NOTICE!
Multifunctional valve: Point of injection with non-
return valve
If you use a mutifunctional valve, then a non-return
valve must be fitted at the point of injection (inte‐
grated in the supplied injection valve). Otherwise,
when the multifunctional valve is activated, the
swimming pool water may flow back via the bypass
line.
1.
With flow sensor: Push the flow sensor into the in-line probe
housing and tighten the reducing nipple and the mounting
clip
2.
Route the sample water feed via a ball valve from the filter
circuit or the sample water pump to the in-line probe housing,
see figures above
3.
Route the sample water feed via a ball valve from the filtra‐
tion circuit to the in-line probe housing or via a free outlet into
the surge water tank, see figures above
4.
Install a 1/2" straight union on the filtration circuit pipe for
each injection valve