26/1
Medium temperature
Moyenne temperature
R404A
R404A
Q
SEPR
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 32°C
Evap. Temp. t = -10°C / Amb. Temp. Ta = + 25°C
Designation
CALCUL
ecodesign
Annual
electric.
consum.
Seasonal
energy
perfom. ratio
Rated
P
A
D
A
compressor
D
A
fan
Rated
D
A
Rated
COP
A
Declared
P
B
D
B
compressor
D
B
fan
Declared
D
B
Declared
COP
B
(kWh/a)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
(kW)
GCV R2SH4EES04 3MS/2V R404A
SEPR
46224
3,29
24,68
10,31
0.96
11,27
2,19
27,65
9,53
0.96
10,49
2,64
GCV R2SH4EES04 3MS/2V SI R404A
SEPR
43424
3,63
25,58
10,09
0.76
10,85
2,36
28,59
9,25
0.76
10,01
2,86
GCV R2SH4EES06 3MS/3V R404A
SEPR
44595
3,61
26,16
9,57
1,40
10,97
2,39
29,24
8,78
1,40
10,18
2,88
GCV R2SH4EES06 3MS/3V SI R404A
SEPR
42612
3,83
26,49
9,49
1.14
10,63
2,50
29,58
8,68
1.14
9,82
3,02
GCV R2SH4DES05 3MS/2V R404A
SEPR
55935
3,14
28,52
12,39
0.96
13,35
2,14
31,97
11,53
0.96
12,49
2,56
GCV R2SH4DES05 3MS/2V SI R404A
SEPR
52622
3,48
29,74
12,10
0.76
12,86
2,32
33,25
11,18
0.76
11,94
2,79
GCV R2SH4DES07 3MS/3V R404A
SEPR
53557
3,55
30,92
11,59
1,40
12,99
2,39
34,49
10,67
1,40
12,07
2,86
GCV R2SH4DES07 3MS/3V SI R404A
SEPR
51308
3,76
31,38
11,48
1.14
12,62
2,49
34,97
10,54
1.14
11,68
3,00
GCV R2SH4CES06 3MS/2V R404A
SEPR
70672
2,91
33,34
15,02
1,40
16,42
2,04
37,43
14,11
1,40
15,51
2,42
GCV R2SH4VES07 3MS/2V R404A
SEPR
72091
2,91
34,10
15,25
1,40
16,65
2,05
38,60
14,38
1,40
15,78
2,45
GCV R2SH4CES06 3MS/2V SI R404A
SEPR
64866
3,31
34,84
14,70
0.76
15,46
2,26
39,02
13,72
0.76
14,48
2,70
GCV R2SH4VES07 3MS/2V SI R404A
SEPR
66792
3,30
35,77
14,93
0.76
15,69
2,29
40,44
14,01
0.76
14,77
2,74
GCV R2SH4CES09 3MS/3V R404A
SEPR
72773
3,14
37,11
14,19
3,00
17,19
2,16
41,45
13,10
3,00
16,10
2,58
GCV R2SH4CES09 3MS/3V SI R404A
SEPR
62926
3,63
37,12
14,19
1.14
15,33
2,43
41,46
13,10
1.14
14,24
2,92
GCV R3SH4EES04 3MS/3V R404A
SEPR
67821
3,42
37,67
15,31
1,40
16,71
2,26
42,17
14,09
1,40
15,49
2,73
GCV R3SH4EES06 3MS/3V R404A
SEPR
73850
3,17
38,01
14,64
3,00
17,64
2,16
42,59
13,52
3,00
16,52
2,58
GCV R3SH4EES04 3MS/3V SI R404A
SEPR
65025
3,64
38,40
15,12
1.14
16,26
2,37
42,92
13,87
1.14
15,01
2,86
GCV R2SH4VES10 3MS/3V R404A
SEPR
73441
3,23
38,48
13,98
3,00
16,98
2,27
43,39
13,08
3,00
16,08
2,70
GCV R2SH4VES10 3MS/3V SI R404A
SEPR
63799
3,71
38,49
13,98
1.14
15,12
2,55
43,40
13,08
1.14
14,22
3,06
GCV R3SH4EES06 4MS/4V SI R404A
SEPR
63696
3,80
39,32
14,34
1.52
15,86
2,48
43,94
13,14
1.52
14,66
3,00
GCV R3SH4DES05 3MS/3V R404A
SEPR
82003
3,28
43,68
18,38
1,40
19,78
2,21
48,89
17,05
1,40
18,45
2,66
GCV R2SH4TES09 3MS/2V R404A
SEPR
83008
3,28
44,27
18,09
1.50
19,59
2,26
49,84
16,90
1.50
18,40
2,71
GCV R3SH4DES05 3MS/3V SI R404A
SEPR
78871
3,49
44,66
18,14
1.14
19,28
2,32
49,93
16,76
1.14
17,90
2,79
GCV R2SH4TES09 3MS/3V SI R404A
SEPR
79536
3,51
45,32
17,87
1.14
19,01
2,39
50,98
16,64
1.14
17,78
2,87
GCV R3SH4DES07 4MS/4V SI R404A
SEPR
77020
3,72
46,49
17,35
1.52
18,87
2,47
51,86
15,98
1.52
17,50
2,97
GCV R2SH4TES12 3MS/3V SI R404A
SEPR
79096
3,63
46,64
17,16
1.65
18,81
2,48
52,44
15,98
1.65
17,63
2,98
GCV R3SH4DES07 3MS/3V R404A
SEPR
85349
3,40
47,13
17,20
3,30
20,50
2,30
52,53
15,79
3,30
19,09
2,76
GCV R2SH4TES12 3MS/3V R404A
SEPR
85778
3,44
47,94
16,90
3,30
20,20
2,38
53,85
15,68
3,30
18,98
2,84
GCV R4SH4EES04 4MS/3V SI R404A
SEPR
88938
3,39
49,00
20,71
1.14
21,85
2,25
54,94
19,16
1.14
20,30
2,71
LEGENDE :