FEATURES
1
Air circulation fan
2
Fuse/s
3
Electronics module (MODAIRFLOW)
4
Spillage monitoring device (TTB) (at rear)
5
Multifunctional control
6
Limit Switch
7
Airflow sensor (Modairflow models)
8
Fan delay control (non modairflow models)
9
Pilot burner
10
Burner and control assembly
11
Data plate
12
Piezo unit
13
Gas connection
14
Electrical assembly
15
Time control
16
Air filter
1.1
HI-SPEC J50 is an open-flued, fan assisted downflow, ducted warm air heater, which may be supplied with MODAIRFLOW
control and in combination with an ELJAN 6 water circulator. A non-MODAIRFLOW version is available as an option.
A Spillage Monitoring Device (TTB) is fitted which senses the temperature in the draught diverter, and shuts down the
appliance when this temperature rises due to the presence of flue gases.
1.2
The air heater output can be adjusted between 11.72kW (42.2MJ/h, 40,000Btu/h) and 14.65kW (57.75MJ/h, 50,000Btu/h).
“Summer air circulation” of unheated air is available by manual selection (see User’s Instructions). ELJAN 6 output is 3.32kW
(11.5MJ/h, 11.340Btu/h).
THIS APPLIANCE CONFORMS TO BS EN 45014
Installation shall be in accordance with the current editions of:
Building Standards (Scotland) (Consolidation) Regulations
Building Regulations
Gas Safety (Installation and Use) Regulations (as amended)
BS 7671 Institute of Electrical Engineers (I.E.E) Wiring Regulations
BS 6891 Installation of Low Pressure Gas Pipework of up to 28mm (R1) in domestic premises (2nd family gases).
BS 5440 Pt. 1 (Flues for Gas Appliances)
BS 5440 Pt. 2 (Air Supply for Gas Appliances)
BS 5864 Installation of Gas Fired Ducted Air Heaters
Model and Local Authority Bye-laws
This appliance has been tested and certified for use with natural gas
1.
BRIEF DESCRIPTION
These instructions are to be left with the User or adjacent to the Gas Meter
Johnson and Starley prides itself on its ability to supply spare parts quickly and efficiently. If you
have a problem in obtaining a spare part, please contact Johnson and Starley Spares Department at
the address below.
JOHNSON & STARLEY LTD.
Telephone:
(01604) 762881
Rhosili Road,
Brackmills,
Fax: (01604) 767408
Northampton NN4 7LZ
Publication No. ZZ 851/6
October 2006
HI-SPEC J50 WARM AIR HEATERS
with MODAIRFLOW and non-MODAIRFLOW Control
INSTALLATION, COMMISSIONING & SERVICING INSTRUCTIONS
G.C. No 42 451 13