Maintenance plan
The yearly inspection must be carried out by a qualified person.
Interval
Daily
Weekly
Monthly
1/2-
year
yearly
Inspect safety features:
•
Vacuum gauge
•
Check that warning (battery test) at correct
underpressure/overpressure values
-
Visual inspection of load securing chain
1)
X
X
Inspect vacuum filter and replace if necessary
X
X
Gasoline motor (see also separate operating instructions)
-
Inspect V-belt, replace if necessary
X
-
Replace V-belt
X
-
Check oil fill level (oil dipstick)
X
-
Change oil
X
-
Inspect air filter
X
-
Replace air filter (more frequently in dusty
environments)
X
-
Inspect spark plug
X
-
Replace spark plug
X
Vacuum pump (see also separate operating instructions)