Operating instruction
MWV250.230 / MWV250.1150
Page
3
Details for general use
After using it is essential to carry out the following operations :
•
Switch off the power switch.
•
Pull out the power plug.
•
Discharge the vacuum by dismantling the siphon pipe at the appliance, thereby the accrued condensation water can flow
out over the quick coupler. (hold the pump a little inclined)
Cleaning and care
•
First pull the connector out of the power outlet.
•
Check damage to the connecting line on a regular basis.
•
Keep the openings of the cooling air free and clean.
•
Check damage to the siphon pipe.
•
Keep oil or corrosion means away from the air route of the vacuum pump.
The filter pad of the outtake cooling air of the engine has to be cleaned every now and then (blow out the compressed air).
If the degree of fouling is too much the filter element has to be replaced.
Damages caused by faulty treatment, capacity overload or usual abrasion are exclused from the warranty.
We assume liability to damages caused by material defects or defects due to manufacturing .
Maintenance and repair
Please consider that repair, maintenance and inspectionof electrical appliances are to be carried out by specialists according to
the national regulations (i.e. VBG 4) because improper repairs may result in major damages for the user.
Maintenance work and repair work are carried out only by our service department.
Spare-parts list
Pos description
ME
Order-No.:
1.
Vacuum pump 230V, 50Hz
Vacuum pump 115V, 60Hz
1
1
AHW27F0.008
AHW27F0.010
2. Motor-circuit
switch
Motor-circuit switch
1
1
EHS088.250
EHS088.630
3. Moulded
Plastic
Enclosure
1
GHK086.002
4. Grommet
1
BHU0252.011
5. Angle
90°
2
LHX101.C
6. Return
valve
1
LHV1607.102
7. Filter
pads
2
240
CE – declaration of conformity
We declare in sole responsibility that this product is according to the following norms or normativ documents :
EN 50 099, EN 292/1, VDE 0530, EN 55 104, EN 55 014, EN 61 000-3-2/-3-3 subject to the regulations:
73/23/EEC, 89/392/EEC und 89/336/EEC.
In case of any alteration which is not coordinated with us, this declaration loses its validity and the warantee lapsed.
5.Angle 90°
LHX101.C (2x)
6.Return valve
LHV1607.102
1.Vacuum pump 230V, 50Hz
115V,60Hz
AHW27F0.008
AHW27F0.010
2.Motor-circuit switch
2,5 / 6,3
EHS088.250
EHS088.630
4.Grommet
BHU0252.011
3.Moulded Plastic
Enclosured
GHK086.002
7.Filter pads
240
Содержание SH-1000-MINI
Страница 22: ...Operating Instructions Installation 21 34 V4 GB Fig 3 Suction plate Spreader bar Vacuum device ...
Страница 36: ......
Страница 40: ......
Страница 46: ...Technische Daten Ersatzteile Vakuumpumpe 27F0 zu VPE 12E 230 50 Stückliste E Pumpe 230V 50Hz Stand 26 01 98 ...
Страница 50: ......