Usage instructions SPEEDY 4all & 4you & 4teen
77
Subsequent inspections are then always per-
formed a year after the last inspection. The
maintenance schedule can be found in the
inspection lists in Chapter 40.
After extreme stresses, such as during holi-
days where the product was exposed to sand,
sea water or snow, an additional deep clean
and inspection by your rehabilitation specialist
dealer is recommended.
To maintain the warranty validity, the perfor-
mance of the maintenance tasks must be doc-
umented. Any faults identified during mainte-
nance work must be rectified and documented
as such before further use of the product.
Even if your product does not show any signs
of wear, damage or malfunctions, the regular
safety-related checks on your product must be
carried out in accordance with the mainte-
nance schedule.
32.3 Proof of maintenance
To provide proof of the maintenance, you can
use the inspection lists in Chapter 40. Always
keep all receipts/service reports as proof, and
have any service work that has not been car-
ried out by the manufacturer documented.
Please bring these usage instructions/the
service booklet along with you each time
maintenance is performed
.
33 Disposal & recycling
At the end of the service life, the product can
be disposed of by PRO ACTIV or your rehabili-
tation specialist dealer in a proper, environ-
mentally-friendly manner.
The disposal or recycling must be carried out
by a waste disposal company or a municipal
waste disposal centre.
Special guidelines may apply on-location with
regard to the disposal or recycling. These must
be clarified and considered when disposing
(this may also include the cleaning or disinfec-
tion of the product before the disposal).
In the following text, you will find a description
of the materials for the disposal and recycling
of the product and its packaging:
Aluminium:
Frame, rims, caster forks, brakes,
back cross bar, side sections, clothing guard,
armrest frame, footrest, footplate support, push
handles
Steel:
Fastening points, quick-release/screwed
axles, push handles, anti-tipping supports,
brakes, armrest frame, screws, nuts
Plastic:
Handles, quick release levers, tube
plugs, caster wheels, armrest padding, tyres,
footplate, side sections, brake lever, anti-
tipping wheels, bags for packing
Synthetic fibres and foam:
padding, covers
Cardboard/paper:
Packaging
34 Re-use
If your product has been provided to you by
your funding provider and you no longer re-
quire it, you should report this fact to your
health insurance company or your rehabilita-
tion specialist dealer. Your product can then be
simply and economically re-used.
Prior to each re-use, a technical safety check
must be carried out on the product at
PRO ACTIV or the rehabilitation specialist
dealer. In addition to the instructions contained
in Chapter 31 (Cleaning and care), a thorough
cleaning of all control elements must be carried
out before using it again.
Before the product can be reused, it must be
prepared with care. A disinfection agent that is
suitable for medical products must be sprayed
onto all surfaces that the user may come into
contact with. A liquid, alcohol-based disinfect-
ant for residue-free, quick disinfection (e.g.
Exporit 4712) must be used for this, and the
respective instructions for use of the disinfect-
ant must be observed. In general, a complete
disinfection cannot be guaranteed on the
seams. We therefore recommend that you
dispose of the seat and backrest upholstery.