HU-TX500-TECH
205
TX500 series technical manual
10.5 Remote Logging Screen
The system provides a remote logging message screen across the network using a TCP/IP
connection. To switch on this feature ensure that the ‘Remote logging screen enabled’ switch
(DIL Switch 5) is set to enabled, see section 5.5 2330 TX Series Control Card.
This screen will show the messages normally displayed on the VGA output which is not
available on the TX rear panels.
The remote logging screen uses the windows Hyperterminal program for this function.
The hyperterminal session needs to be configured to use a TCP/IP (winsock) connection
using the appropriate IP (TX IP) and Port (GenMsgPort value in NETWORK.ini file) address.
General text based logging messages are displayed all the time.
Various bits of logging information to do with data received/transmitted on the various ports
can be toggled on/off by entering numbers on the keyboard followed by carriage return
(<CR>).