HU-TX500-TECH
157
TX500 series technical manual
9.5.3 Speaker Monitoring
The speaker monitoring
function sets the operation of the
<CUT>
and
<DIM>
speaker
monitoring buttons. When set to
<DIM>
, the buttons operate as
<CUT>
and
<DIM>
buttons
exclusively, where
<CUT>
represents a complete silence in the audio and
<DIM>
represents
a 12dB reduction in the level. When set to
<CUT R>
the
<DIM>
button operates as a cut
right with
<CUT>
being cut left and the buttons no longer operate mutually exclusively.
9.5.4 Stop Watch Mode
The button
<TOD> / <TIMER>
provides toggle operation, allowing either stop watch mode
or segment/remaining timer mode to be available on the timer home page. The button
legend displays the current state, either TOD or Timer.
9.5.5 Key Functions
There are two key functions
<KEY FNS>
buttons on this screen. These buttons, in
conjunction with internal control panel cabling, enable the function of two groups of buttons
in the top left corner of the panel to be specified. The function control, and the buttons they
relate to on the panel is as detailed in the diagram below.
TOD
Home
8 x 1
Bypas
Auto
Key
Fns
Available functions for these buttons are:
•
8x1 Bypass
This mode enables the panel to control an 8x1 router for use as an emergency
bypass router. (Top set of buttons only)
•
Automation
The buttons operate as a manual intervention panel, MIP, for Pro-Bel automation
systems. (Lower set of buttons only)
•
VTR control
The buttons provide basic VTR transport control. (Available to either group of
buttons)
•
Multi Channel Assign