Prism
Operation Manual Issue 2.00
Page 6.3
Figure 6.1. - DSA-1 V2.0 Menus Summary
1.
Carrier Tests
1.1.
fs Freq
Measures sampling rate
1.2.
fs Jitter
Measures fs (source) Jitter
[EDIT] toggles PLL CF
1.3.
Data Jitter
Measures Data (total) Jitter
[ENTER] toggles ns/UI mode
1.4.
Amplitude
Measures carrier amplitude
1.5.
Eye Closure
Measures loss of eye width
[EDIT] toggles ZeroX/200mV
1.6.
Errors
Displays biphase error count
[CLEAR] clears to zero
1.7.
Phase v Ref
Measures
1
wrt Ref Sync
[EDIT] toggles degrees/%
1.8.
CM Ampl
Measures common-mode ampl
1.9.
LoBand Ampl
Measures sub-20kHz ampl
1.10. Log Carrier
Runs Carrier Tests to log
2.
Data Tests
[EDIT] toggles peak-hold on/off
2.1.
Audio Meter
Audio bargraph and readout
[NEXT] selects no-read/dBFS/hex
2.2.
Active Bits
Displays audio-bit activity
[<],[>] toggle mono/stereo
2.3.
C-S Fields
Channel Status by field
[<],[>] select field, [EDIT] as 2.6.
2.4.
C-S Bytes
Channel Status by byte
[<],[>] select byte
2.5.
C-S Idents
Channel Status alpha labels
2.6.
C-S Timecode Channel Status timecodes
[EDIT] toggles smps/bcd time mode
2.7.
Log Data
Runs Data Tests to log
3.
Test Sequence
3.1.
Run
Runs selected sequence
[ENTER] restarts sequence
3.2.
Select
Selects desired sequence
[<],[>] select restart segment
3.3.
Log Sequence Runs selected sequence to log
[ENTER],[<],[>] as 3.1.
4.
Generator
4.1.
Sync Source
Selects int/ext sync or DI
[NEXT] selects field to adjust
4.2.
Edit Modes
GEN1: sets params to edit
[<],[>] adjust selected field
4.3.
Audio Func
Selects GEN1/GEN2, & fn
[CLEAR] may select default value
4.4.
Audio Params
ON/OFF, freq, ampl, word
4.5.
Chan Status
GEN1: C-S edits, GEN2: P/C
In 4.5., GEN1:
4.6.
C-S Capture
Loads input C-S to GEN1
[ENTER] toggles select/adjust mode
4.7.
Valid Bit
GEN1: sets gen Validity bit
[<],[>] select field or adjust value
4.8.
Jitter Gen
GEN2: gen jitter fn & ampl
[EDIT] toggles field edit on/off
4.9.
Log Gen
Writes generator setup to log
5.
Channel Check
[NEXT] display count/time or Event
5.1.
Run to Log
Logs bit-errors against time
[<],[>] scroll thru Event display
5.2.
Setup
Sets channels, word-length
[NEXT] selects field to adjust
[<],[>] adjust selected field
6.
Watchdog
6.1.
Run to Log
Logs panel LEDs against time
[NEXT],[<],[>] as 5.1.
6.2.
Setup
Selects LEDs to be watched
[<],[>],[EDIT] set LEDs to watch
7.
Microscope
Digital gain for monitoring low-
[NEXT] selects field to adjust
level signals, with clip indicators [<],[>] adjust selected field
8.
Results Log
8.1.
Start Block
Inserts block marker in log
8.2.
Print Log
Sends log to serial printer
[<],[>] go one line back or forward
8.3.
Clear Log
Clears contents of log
[NEXT] goes to start of next block
8.4.
Log Viewer
Views log line by line
[CLEAR] goes to start of log
8.5.
Blk Manager
Prints, clears individual blks
[<],[>] go one blk back or forward
8.6.
Form Feed
Sends form-feed to printer
[NEXT] prints the current block
[CLEAR] deletes the current block
9.
System Setup
9.1.
Settings
Adjusts system settings
[<],[>] scroll through settings
9.2.
Save Set-up
Saves settings as power-up
[EDIT] adjusts current setting
9.3.
Defaults
Sets defaults (doesn't save)
[<],[>] toggle learn/display modes
9.4.
Ref Learn
Soft-cal for fs-measurement
[ENTER],[CLEAR] acquire or clr cal
9.5.
Battery Chg
Starts fast-charge of battery
[ENTER] skips discharge phase
9.6.
Host Mode
Interacts with host PC