OTHER FEATURES
5-5
PA1628 H3-41, H3-45 Operator’s Manual
Initiating a Stationary (Parked) Regeneration
NOTE
At starting of the engine, if a stationary
regeneration is required, the engine coolant
temperature must reach 140°F (60°C) before
any stationary regeneration may be initiated
and completed. Permit the engine to idle for a
short while or drive the vehicle until engine
temperature increases sufficiently.
WARNING
Do not initiate a stationary regeneration in a
closed area like a garage. Stationary
regenerations must be undertaken outdoors
only.
WARNING
During stationary regeneration, exhaust
temperature may reach up to 1200°F
(650°C) at the particulate filter. Before
initiating stationary regeneration, make
sure that the DPF outlet diffuser is clear of
objects and that no one is working near the
DPF outlet diffuser.
WARNING
Hot surfaces. Keep yourself clear of all hot
Aftertreatment Device components,
particularly during and after active or
stationary regeneration. Hot surfaces can
cause serious burns.
NOTE
STATIONARY REGENERATION
This process requires the vehicle to be parked
while the driver or a maintenance technician
initiates the regeneration process.
The DPF REGENERATION telltale light illuminates
to notify the driver of the need and urgency of a
manual stationary regeneration.
DPF REGENERATION telltale light
If stationary regeneration is not performed, this
telltale light will blink, indicating that a
stationary regeneration is required immediately.
If stationary regeneration is still not performed,
“engine power derate and shutdown” sequence
may occur as per level 1 to level 4 sequence.
To initiate a stationary regeneration:
Park the vehicle in a clear area, vehicle speed
must be 0 mph (0 km/h);
Engine must be on normal idle and fully
warmed up (coolant temperature above
140°F/60°C);
Apply parking brakes and set the
transmission to neutral (N).
Press the DID ENTER button and then get to
the DID Aftertreatment menu. Select sub-
menu Request Parked REGEN and press
ENTER button to confirm and initiate
regeneration.
The regeneration will begin. Turn off the air
conditioning to reduce engine load. The engine
idling speed will increase to 1600 rpm. Once the
regeneration is completed, the engine speed will
return to normal idle.
Voluntary Interruption of a Stationary
Regeneration
It is possible to interrupt a stationary
regeneration at all time. To do so, get to the
DID’s Aftertreatment menu, select Cancel REGEN
and press ENTER button to confirm. You can
stop regeneration simply by releasing the parking
brake. Use this procedure in order to move the
vehicle in a safe area only.
If regeneration is interrupted, it is very important
to reinitiate the regeneration as soon as possible.
Содержание H 2018 Series
Страница 1: ...COACH MANUFACTURER OPERATOR S MANUAL H SERIES COACHES PA1628 January 2018 ...
Страница 8: ......
Страница 10: ......
Страница 14: ......
Страница 17: ...COACH EXTERIOR 2 3 PA1628 H3 41 H3 45 Operator s Manual EXTERIOR LIGHTING 18588_7A EXTERIOR LIGHTING ...
Страница 30: ......
Страница 114: ......
Страница 215: ...TECHNICAL INFORMATION 9 3 PA1628 H3 41 H3 45 Operator s Manual H3 41 OVERALL DIMENSIONS 18527_2 ...
Страница 216: ...9 4 TECHNICAL INFORMATION PA1628 H3 41 H3 45 Operator s Manual H3 41 OVERALL DIMENSIONS 18527_3 ...
Страница 217: ...TECHNICAL INFORMATION 9 5 PA1628 H3 41 H3 45 Operator s Manual H3 45 OVERALL DIMENSIONS 18525 ...
Страница 218: ...9 6 TECHNICAL INFORMATION PA1628 H3 41 H3 45 Operator s Manual H3 45 OVERALL DIMENSIONS 18525_2 ...
Страница 232: ......
Страница 236: ......
Страница 256: ......