5-4 OTHER FEATURES
PA1628 H3-41, H3-45 Operator’s Manual
DIESEL PARTICULATE FILTER CLOGGING SEQUENCE – INSTRUMENT CLUSTER TELLTALE LIGHT
LEVEL
1
solid
REGENERATION NEEDED
Diesel particulate filter is becoming full
The DPF REGENERATION telltale light illuminates to notify the driver that a
stationary regeneration (parked) will be required soon. When this lamp is lit,
initiate stationary regeneration process at an appropriate time of day.
THERE
IS NO URGENCY AT THIS LEVEL
.
LEVEL
2
flashing
REGENERATION REQUIRED
Diesel particulate filter full
If no DPF regeneration occurs after the initial DPF REGENERATION telltale
light illumination, the lamp will begin blinking and a stationary regeneration
should be initiated as soon as possible in order to prevent from entering into
Level 3.
LEVEL
3
flashing
+
ATD SERVICE REQUIRED
ENGINE DERATE ACTIVE
Diesel particulate filter overfull
If the flashing DPF REGENERATION telltale light is still ignored, the CHECK
telltale light will illuminate. In that situation, engine performance is limited.
Perform a parked regeneration IMMEDIATELY to avoid further derate and
prevent from entering into Level 4.
LEVEL
4
flashing
+
+
ATD SERVICE REQUIRED
ENGINE SHUTDOWN ACTIVE
A serious engine problem has occurred. The DPF may be over its maximum
capacity.
If a stationary regeneration is still not initiated, a standard Engine Protection
Shutdown sequence will occur. All of the following dashboard lamps will be
present:
Blinking DPF REGENERATION telltale light;
Solid CHECK telltale light;
Solid STOP telltale light.
Once engine derate and/or shutdown sequence is completed, a stationary
regeneration must occur to continue vehicle operation. If the driver continues
to operate the vehicle without regeneration, additional measures will be
taken to protect the engine and ATD from damage, up to and including
engine shutdown. Parked regeneration might no longer be possible.
If engine protection has been initiated and forces the engine to
shutdown, you CAN immediately re-start the engine and perform the
necessary steps in order to initiate a stationary regeneration.
Find and solve the cause of the shutdown
Содержание H 2018 Series
Страница 1: ...COACH MANUFACTURER OPERATOR S MANUAL H SERIES COACHES PA1628 January 2018 ...
Страница 8: ......
Страница 10: ......
Страница 14: ......
Страница 17: ...COACH EXTERIOR 2 3 PA1628 H3 41 H3 45 Operator s Manual EXTERIOR LIGHTING 18588_7A EXTERIOR LIGHTING ...
Страница 30: ......
Страница 114: ......
Страница 215: ...TECHNICAL INFORMATION 9 3 PA1628 H3 41 H3 45 Operator s Manual H3 41 OVERALL DIMENSIONS 18527_2 ...
Страница 216: ...9 4 TECHNICAL INFORMATION PA1628 H3 41 H3 45 Operator s Manual H3 41 OVERALL DIMENSIONS 18527_3 ...
Страница 217: ...TECHNICAL INFORMATION 9 5 PA1628 H3 41 H3 45 Operator s Manual H3 45 OVERALL DIMENSIONS 18525 ...
Страница 218: ...9 6 TECHNICAL INFORMATION PA1628 H3 41 H3 45 Operator s Manual H3 45 OVERALL DIMENSIONS 18525_2 ...
Страница 232: ......
Страница 236: ......
Страница 256: ......