61
5.2.14
TRG Command
Short description:
The command TRG is a Wait For Trigger. The command enables an exact alignment of the sensors sampling intervals with the movement of a scanning
axis.
It stops the sensor after completion of the current data telegram and puts it in a waiting state. This state is left by a trigger event (rising edge on the Sync
in, Encoder Trigger).
Command syntax:
$TRG
Command
Description
NET
$TRG
Response: $TRG[CR]ready[CR/LF].
Wait For Trigger
client.TriggerStartStop();