67
Maintenance
7.1
How to change fans
The goal of this document is to explain how to change the heat sink’s fans as a replacement. Inside
the CHRocodile CLS, there are two fans which allow to dissipate heat induce by light source and
electronic boards. In case of fans malfunctioning, temperature inside the CHRocodile unit will
increase. A thermal switch has been integrated inside the line sensor unit. This thermal switch is a
protection against high temperature which could damage the device, and it consists in power off the
line sensor unit when too high temperature occurs.
Therefore, when the line sensor CHRocodile turns
off unexpectedly, check the fan operation.
Fig 7-11: Fan: COPAL F310-12LB
Step by step procedure
Fig 7-12: Steps 1 and 2
1
2