Chapter 5 Function parameter
57
Ch
ap
ter 5
9 8 7 6 5 4 3 2 1 0
2
9
8
7
6
5
4
3
2
1
0
Reserved
DI8
DI7
DI1
DI2
DI3
DI4
DI5
DI6
2
2
2
2
2
2
2
2
2
Reserved
Diagram 5-1:
DI1 the sequence of the input terminal
d0.08
DO output status
-
DO output status, this value is a hexadecimal digits. The table listed each output terminal status
sequence for each bit:
0 to 10 bits
Output terminal status
0
Invalid
1
Valid
4 3 2 1 0
2
4
3
2
1
0
SPB
Relay 1
The manufacturer reserves the undefined
SPA
Relay 12
2 2
2 2
Diagram 5-2:
DO the sequence of the Output terminal
d0.09
AI1 voltage (V)
0.01V
AI1 input voltage value
d0.10
AI2 voltage (V)
0.01V
AI2 input voltage value
d0.11
Panel potentiometer voltage (V)
0.01V
AI3 input voltage value
d0.12
Count value
-
Actual pulse count value in counting function
d0.13
Length value
-
Actual length in fixed length function
d0.14
Actual speed
-
Motor Actual running speed display
d0.15
PID setting
%
Reference value percentage under PID adjustment mode
d0.16
PID feedback
%
Feedback value percentage under PID adjustment mode
d0.17
PLC stage
-
Stage display when PID program is running
d0.18
High-speed pulse input pulse frequency (Hz)
0.01kHz
High-speed pulse input frequency display, unit: 0.01Khz
d0.19
Feedback speed(unit:0.1Hz)
0.1Hz
PG feedback speed, to an accuracy of 0.1hz
d0.20
Remaining run time
0.1Min
Remaining run time display, it is for timing run control
d0.21
Linear speed
1m/Min
Show the line speed of DI5 high speed pulse sampling, according to the actual sample pulse
number per minute and E0.07, calculate the line speed value.
d0.22
Current power-on time
1Min
Total time of current inverter power-on