Chapter 5 Function parameter
51
Ch
ap
ter 5
426.
E3.09
Panel potentiometer as a function
selection of DI
0 to 50
427.
E3.10 AI as DI effective mode selection
Units digit
:
AI1
0:High level effectively
1:Low level effectively
Tens digit:AI2(0 to 1,same as
units digit)
Hundreds digit: Panel
potentiometer(0 to 1,same as
units digit)
000
★
428.
E3.11
Virtual VDO1 output function
selection
0 to 40
0
☆
429.
E3.12 Virtual VDO2 output function
0 to 40
0
☆
430.
E3.13 Virtual VDO3 output function
0 to 40
0
☆
431.
E3.14 Virtual VDO4 output function
0 to 40
0
☆
432.
E3.15 Virtual VDO5 output function
0 to 40
0
☆
433.
E3.16
VDO output terminal effective
status selection
Units digit:VDO1
0:Positive logic
1:Negative logic
Tens digit: VDO2(0 to 1,same as
above)
Hundreds digit:VDO3(0 to
1,same as above)
Thousands digit:VDO4(0 to
1,same as above)
Tens of thousands digit:VDO5
(
0 to 1,same as above
)
00000
☆
434.
E3.17 VDO1 output delay time
0.0s to 3600.0s
0.0s
☆
435.
E3.18 VDO2 output delay time
0.0s to 3600.0s
0.0s
☆
436.
E3.19 VDO3 output delay time
0.0s to 3600.0s
0.0s
☆
437.
E3.20 VDO4 output delay time
0.0s to 3600.0s
0.0s
☆
438.
E3.21 VDO5 output delay time
0.0s to 3600.0s
0.0s
☆
5-1-19.
b0 Group -Motor parameters
No. Code
Parameter name
Setting range
Factory
setting
Chan
ge
439.
b0.00
Motor type selection
0: general asynchronous motor
1: asynchronous inverter motor
2: permanent magnet
synchronous motor
0
★
440.
b0.01 Rated power
0.1kW to 1000.0kW
Depends
on models
★