Chapter 5 Function parameter
106
Ch
ap
ter 5
Diagram 5-31:
Schematic diagram of simple PLC
E1.17
Simple PLC power-down
memory selection
Units digit power-down memory selection
00
☆
power-down without memory
0
power-down with memory
1
Tens digit
stop memory selection
stop without memory
0
stop with memory
1
PLC "Power-Down With Memory" means that the PLC operating stage and frequency before
power-down are memorized, and then it will continue to run from the position of the memorized
stage in next power-on. If Power-Down Without Memory is selected, the PLC process will restart
from the starting position for each power-on
PLC "Stop With Memory" means that the PLC operating stage and frequency before stop are
recorded, and then it will continue to run from the position of the recorded stage in next run. If
Stop Without Memory is selected, the PLC process will restart from the starting position for each
start.
E1.18 0 stage running time T0
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.19 0 stage ac/deceleration time selection
0 to 3
0
☆
E1.20 1 stage running time T1
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.21 1 stage ac/deceleration time selection
0 to 3
0
☆
E1.22 2 stage running time T2
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.23 2 stage ac/deceleration time selection
0 to 3
0
☆
E1.24 3 stage running time T3
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.25 3 stage ac/deceleration time selection
0 to 3
0
☆
E1.26 4 stage running time T4
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.27 4 stage ac/deceleration time selection
0 to 3
0
☆
E1.28 5 stage running time T5
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.29 5 stage ac/deceleration time selection
0 to 3
0
☆
E1.30 6 stage running time T6
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.31 6 stage ac/deceleration time selection
0 to 3
0
☆
E1.32 7 stage running time T7
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.33 7 stage ac/deceleration time selection
0 to 3
0
☆
E1.34 8 stage running time T8
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.35 8 stage ac/deceleration time selection
0 to 3
0
☆
E1.36 9 stage running time T9
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.37 9 stage ac/deceleration time selection
0 to 3
0
☆
E1.38 10 stage running time T10
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.39 10 stage ac/deceleration time selection
0 to 3
0
☆
E1.40 11 stage running time T11
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.41 11 stage ac/deceleration time selection
0 to 3
0
☆
E1.42 12 stage running time T12
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.43 12 stage ac/deceleration time selection
0 to 3
0
☆
E1.44 13 stage running time T13
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.45 13 stage ac/deceleration time selection
0 to 3
0
☆
E1.46 14 stage running time T14
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.47 14 stage ac/deceleration time selection
0 to 3
0
☆
E1.48 15 stage running time T15
0.0s(h) to 6500.0s(h)
0.0s(h)
☆
E1.49 15 stage ac/deceleration time selection
0 to 3
0
☆
Multi-speed operation and deceleration time selection 0 to 3 , corresponding to the function
code: