• Check fuse(s) and circuit breaker(s). Replace any
blown fuse(s) with a fuse of equal specification.
• Make sure the correct voltages are present at the
proper locations inside the control panel(s).
Before performing the detailed troubleshooting procedures, check the following items first:
Symptom
Possible Cause
Solution
Platform does not rise.
Motor does not energize.
Motor overload device
tripped.
Reset overload relay or breaker. Determine cause of
device tripping.
Motor starter (three-
phase) or motor relay
(single-phase) not
energizing.
Check voltage at starter or relay coil.
• If voltage is present and starter or relay does not
energize, replace starter or relay.
• If voltage is not present, check all components in
series with the starter or relay coil.
Three-phase units only:
Platform does not rise.
Motor runs in reverse
Phase reversed.
Reverse any two legs at the branch circuit
disconnect.
When service under the dock leveler is required,
always lock all electrical disconnects in the OFF
position after raising the platform and engaging the
maintenance prop.
Always post safety warnings and barricade the
work area at dock level and ground level to prevent
unauthorized use of the dock leveler before
maintenance is complete.
A hard hat or other applicable head protection
should always be worn when working under or
around a dock leveler.
Always stand clear of platform lip when working in
front of the dock leveler.
Unless the dock leveler is equipped with a tethered
remote, two people are required to engage the
maintenance prop: one person to operate the unit,
the other person to engage the maintenance prop.
In addition, it is recommended and good safety
practice to use an additional means to support
the dock platform and lip anytime when physically
working in front of or under the dock leveler. This
additional means may include, but is not limited to a
boom truck, fork truck, stabilizing bar or equivalent.
TROUBLESHOOTING
Содержание LHP Series
Страница 13: ...11 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank INSTALLATION ...
Страница 25: ...23 4111 0012 Sept 2018 2018 Systems LLC INSTALLATION This page intentionally left blank ...
Страница 31: ...29 4111 0012 Sept 2018 2018 Systems LLC MAINTENANCE This page intentionally left blank ...
Страница 42: ...40 4111 0012 Sept 2018 2018 Systems LLC PARTS B A D C Lip and Platform Parts ...
Страница 47: ...45 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 49: ...47 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 50: ...48 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank MISCELLANEOUS ...