Symptom
Possible Cause
Solution
Lip does not stay
extended when leveler
lowers.
Faulty lip cylinder.
Replace lip cylinder.
Platform DOES rise to
full height, but lip DOES
NOT extend or extend
fully.
Sequence Valve requires
adjustment.
Adjust valve as necessary. See page 33 for
adjustment instructions.
Lip does not extend.
Sequence Valve requires
adjustment.
Adjust valve as necessary. See page 33 for
adjustment instructions.
Lip extends almost
immediately when
the RAISE button is
depressed.
Sequence Valve requires
adjustment.
Adjust valve as necessary. See page 33 for
adjustment instructions.
Platform locks into
“safety” as platform
lowers. Lip drops to
vertical position.
Faulty velocity fuse.
Replace velocity fuse.
Incorrect or aged hydraulic
fluid.
Replace hydraulic fluid, see pages 30-31 for proper
fluid level and type.
Technical Service at 800-643-5424 or [email protected]
If additional troubleshooting assistance is required, contact Systems, LLC
Technical Services with equipment serial number or customer order number (CO#).
TROUBLESHOOTING
Содержание LHP Series
Страница 13: ...11 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank INSTALLATION ...
Страница 25: ...23 4111 0012 Sept 2018 2018 Systems LLC INSTALLATION This page intentionally left blank ...
Страница 31: ...29 4111 0012 Sept 2018 2018 Systems LLC MAINTENANCE This page intentionally left blank ...
Страница 42: ...40 4111 0012 Sept 2018 2018 Systems LLC PARTS B A D C Lip and Platform Parts ...
Страница 47: ...45 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 49: ...47 4111 0012 Sept 2018 2018 Systems LLC PARTS This page intentionally left blank ...
Страница 50: ...48 4111 0012 Sept 2018 2018 Systems LLC This page intentionally left blank MISCELLANEOUS ...